A new class of
heat exchanger

Your flow. Your temperatures. Your pressures.
One piece of metal, printed to match.
The most important part of your CDU is the one you didn't design.
Air can't keep up with rack power, and your customers want density you can't ship. The limit is your heat exchanger: stamped, brazed, and in every competitor's cabinet.
What if that limit became your edge?
- 5–15%
- of your bill of materials
- 100%
- of your thermal ceiling
Modern data centers need top-performing CDUs.
Performance starts with Phasic.‡
- * Figures assume a 100 MW site, wholesale colocation rates and PUE 1.4.
- † A smaller core removes what forces a bigger enclosure or a second unit.
- ‡ Each part is designed to your duty point; competitors specify from the same five suppliers.
It all comes down to geometry.
Shapes that can’t be drawn by hand or stamped by a press.

01
AI designs it
Our AI is trained on more than 80,000 CFD simulations. It takes your duty point and returns printable CAD in about a minute, generating novel geometries that a thermal engineer, a CFD analyst and a CAD designer would spend months converging on.

02
Every passage tuned to your duty point
Ports, ducts and channels change shape together until the part fits your pressure-drop ceiling and meets the target you put first: approach temperature or size. Our AI tunes the hot and cold sides separately, which a stamped plate cannot do.

03
Printed as one piece of metal
No plate pack. No braze. No gaskets. One printed part, in stainless or aluminium, with no joint anywhere for a coolant to find.

A 500kW build, measured.
Not a catalog part. A Phasic core built for approach temperature, against a conventional brazed plate at the same duty and about the same volume. Set a different target and these numbers move.
| Metric | Phasic | Conventional Brazed Plate |
|---|---|---|
| Duty | 500kW | 500kW |
| Approach Temp. | 2.5°C | 3.6°C |
| Volume | 94L | 97.5L |
| Pressure Drop | Inside your budget | .50 to .65 bar |
| Parts | 1 solid part | About 180 plates |
| Construction | printed SS316L | Stamped and brazed |
Best design to date: about 60% lower approach temperature than a brazed plate in the same envelope, modelled at a different duty.
Three loop architectures on one platform.


Liquid-to-Liquid
100 kW to multi-megawatt
The core of the CDU. Facility water on one side, the technology loop on the other.


Two-Phase
Kilowatt class, modular
Condensers and evaporators for pumped refrigerant loops, where single-phase runs out.


Air-to-Liquid
10 to 100 kW
Rear-door and in-row. Captures rack exhaust at the source, with no containment rework.
Send us a duty point
Share your cooling requirements with our engineering team.